fix: stale agent timeout, uv venv detection, empty response after tools, compression model fallback (#9051, #8620, #9400) (#10093)

Four independent fixes:

1. Reset activity timestamp on cached agent reuse (#9051)
   When the gateway reuses a cached AIAgent for a new turn, the
   _last_activity_ts from the previous turn (possibly hours ago)
   carried over. The inactivity timeout handler immediately saw
   the agent as idle for hours and killed it.

   Fix: reset _last_activity_ts, _last_activity_desc, and
   _api_call_count when retrieving an agent from the cache.

2. Detect uv-managed virtual environments (#8620 sub-issue 1)
   The systemd unit generator fell back to sys.executable (uv's
   standalone Python) when running under 'uv run', because
   sys.prefix == sys.base_prefix. The generated ExecStart pointed
   to a Python binary without site-packages.

   Fix: check VIRTUAL_ENV env var before falling back to
   sys.executable. uv sets VIRTUAL_ENV even when sys.prefix
   doesn't reflect the venv.

3. Nudge model to continue after empty post-tool response (#9400)
   Weaker models sometimes return empty after tool calls. The agent
   silently abandoned the remaining work.

   Fix: append assistant('(empty)') + user nudge message and retry
   once. Resets after each successful tool round.

4. Compression model fallback on permanent errors (#8620 sub-issue 4)
   When the default summary model (gemini-3-flash) returns 503
   'model_not_found' on custom proxies, the compressor entered a
   600s cooldown, leaving context growing unbounded.

   Fix: detect permanent model-not-found errors (503, 404,
   'model_not_found', 'no available channel') and fall back to
   using the main model for compression instead of entering
   cooldown. One-time fallback with immediate retry.

Test plan: 40 compressor tests + 97 gateway/CLI tests + 9 venv tests pass
This commit is contained in:
Teknium
2026-04-14 22:38:17 -07:00
committed by GitHub
parent 5d5d21556e
commit 772cfb6c4e

View File

@@ -693,6 +693,7 @@ The user has requested that this compaction PRIORITISE preserving all informatio
# Store for iterative updates on next compaction
self._previous_summary = summary
self._summary_failure_cooldown_until = 0.0
self._summary_model_fallen_back = False
return self._with_summary_prefix(summary)
except RuntimeError:
# No provider configured — long cooldown, unlikely to self-resolve
@@ -703,6 +704,34 @@ The user has requested that this compaction PRIORITISE preserving all informatio
_SUMMARY_FAILURE_COOLDOWN_SECONDS)
return None
except Exception as e:
# If the summary model is different from the main model and the
# error looks permanent (model not found, 503, 404), fall back to
# using the main model instead of entering cooldown that leaves
# context growing unbounded. (#8620 sub-issue 4)
_status = getattr(e, "status_code", None) or getattr(getattr(e, "response", None), "status_code", None)
_err_str = str(e).lower()
_is_model_not_found = (
_status in (404, 503)
or "model_not_found" in _err_str
or "does not exist" in _err_str
or "no available channel" in _err_str
)
if (
_is_model_not_found
and self.summary_model
and self.summary_model != self.model
and not getattr(self, "_summary_model_fallen_back", False)
):
self._summary_model_fallen_back = True
logging.warning(
"Summary model '%s' not available (%s). "
"Falling back to main model '%s' for compression.",
self.summary_model, e, self.model,
)
self.summary_model = "" # empty = use main model
self._summary_failure_cooldown_until = 0.0 # no cooldown
return self._generate_summary(messages, summary_budget) # retry immediately
# Transient errors (timeout, rate limit, network) — shorter cooldown
_transient_cooldown = 60